  • Kit includes:
    • ​1 can Enviro-Safe Proseal XL4 #2100a
    • 1 can Enviro-Safe Prodry XL4 #2105a
    • 1 each R12/22/502 hose with top tap #3345
  • Aerosol
  • Forms a hard seal on metal, schrader valves, o’rings, gaskets, a/c condensers, evaporators, line sets and solder joints
  • Enviro-Safe Proseal XL4 repairs minor leaks in home, heat pump, large auto, and industrial applications
  • One can will normally repair a leak in systems up from 1.5 to 5 ton. If you have a smaller unit, please contact us.
  • If the a/c system that will not hold a vacuum, you need to use the Enviro-Safe Prodry XL4.
  • The reason for the vacuum or the use of Enviro-Safe Prodry XL4 is that it will eliminate moisture in the system. Moisture mixing with oils and refrigerant can cause you system to make sulfuric acid which will corrode and eat your system!
  • For larger units over 5 tons, we suggest you use the Enviro-Safe Proseal XL4 Direct Inject. These are available in various of the larger sizes.
  • Even though Proseal XL4 can form a seal on the Schrader valve, when you hook up to it the seal will release and allow you to use the Schrader if necessary. If there is still Proseal XL4 in the system it will reseal the Schrader.
  • Can be used as a system-protector against system failure.
  • Protects against leaks formed by corrosion.
  • Enviro-Safe ProDry contains a dehydrating agent that converts system moisture into oil. We recommend the use of ProDry XL4 before the use of Enviro-Safe ProSeal XL4 to ensure all moisture has been removed from the air conditioning system.
  • Should be used on any home A/C system that has leaked below 15 psi (running or not running) or if the system has ever leaked below 15 psi in the past.  If you do not wish to use Pro Dry XL4, the system must be vacuumed prior to installing ProSeal XL4.
  • When put into an A/C system that has moisture or air, Pro Dry XL4 mixes with the moisture and air in system forming a synthetic oil which then mixes with the oil in the system.
  • DO NOT use in ammonia systems
  • DO NOT use in CO2 systems
  • DO NOT use in R410a systems- Pressure is too high and will explode the can- You MUST use the Enviro-Safe Proseal XL4 Direct Inject line of products.
  • Cannot be sent to Alaska or Hawaii or exported to foreign countries except in pallet quantities
  • Gas propelled
  • Installs the same way as refrigerant
  • Cannot be added to a fully charged system

Proseal XL4 for R22 Systems

Read and understand all warnings and directions before use. DO NOT use with ammonia. As per use with any flammable substance, take adequate precautions during use. 
1. A/C must be operating before installing Proseal XL4. 
2. Shake can well. 
3. Install can tap valve and charging hose. 
4. Install charging hose on the low pressure side ONLY. 
5. Invert can. 
6. Install all Proseal XL4 from can. 
7. Fill system to correct pressure. 
8. DO NOT overcharge the A/C system. 
9. Run the system for 45 minutes to circulate the Proseal XL4. 
10. Dispose of waste material in accordance with all local, regional, national, and international regulations. 
Note: This can will treat a typical 1.5-5 ton home A/C system. This product will repair most small leaks in evaporators, condensers, and fittings. 

Prodry XL4 for R22 Systems

Read and understand all warnings and directions before use. DO NOT use with ammonia. As per use with any flammable substance, take adequate precautions during use. This product is recommended to use prior to installing Enviro-Safe ProDry XL4 in the system.
1. A/C must be operating before installing ProDry XL4. 
2. Shake can well. 
3. Install can tap valve and charging hose.
4. Install charging hose on the low pressure side ONLY. 
5. Invert can. 
6. Install all ProDry XL4 from can. 
7. Fill system to correct pressure. 
8. DO NOT overcharge the A/C system. 
9. Run the system for 30 minutes to circulate the ProDry XL4. 
10. For systems with excessive moisture, additional ProDry XL4 may be required. 
11. Dispose of waste material in accordance with all local, regional, national, and international regulations. 
Note: This can will treat a typical 1.5-5 ton home A/C system. This product will repair most small leaks in evaporators, condensers, and fittings. 

Customers Also Bought:

Enviro-Safe 134a Replacement Refrigerant w/ Stop Leak Cans & Cases - Click to Purchase

Enviro-Safe 134a Replacement Refrigerant w/ Stop Leak Cans & Cases

Our newest refrigerant product!!


Please select an option from the list:

Price/Option: Quantity:

ProSeal & ProDry w/ Leak Detector for 134 Systems 3 oz Can/Cases - Click to Purchase

ProSeal & ProDry w/ Leak Detector for 134 Systems 3 oz Can/Cases

For more information please click the link above.


Please select an option from the list:

Price/Option: Quantity:

Newsletter Signup: